Preview

Translational Medicine

Advanced search

Detection of blast cells on the Mindray MC-80 automatic blood cell analyzer

https://doi.org/10.18705/2311-4495-2026-13-4-388-398

Abstract

Background. Detection of blast cells in peripheral blood is crucial for the diagnosis, monitoring, and evaluation of treatment efficacy in hematological diseases. The introduction of digital morphology can improve the standardization of laboratory processes; however, the results of automatic preclassification require evaluation of their comparability with expert morphological assessment. Objective. To evaluate the comparability of the results of automatic blast cell preclassification and counting using the Mindray MC-80 digital morphology analyzer with the results of expert morphological verification of digital images of peripheral blood smears. Materials and Methods. The study included 205 patients with various hematological pathologies and the presence of blasts in their peripheral blood. Blast cell counts were assessed using the Mindray MC-80 and by expert verification by a morphologist. Statistical analysis included Spearman correlation, Passing-Bablok regression, and Bland-Altman analysis. Results. Blasts were detected in all smears by expert morphological verification, while automatic counting detected them in 95.1 % of cases. A highly statistically significant correlation was found between the methods: r=0.806; p<0.0001. Mindray MC-80 statistically significantly overestimated the blast count compared to EV. According to the regression model constructed on the Bland-Altman plot, the average difference between the results of Mindray MC-80 automatic preclassification and expert verification was 2.1 cells (95 % CI of the mean difference 1.2–3.0) with an average blast count of 0.5 per 200 leukocytes and increased to 5.5 cells (95 % CI of the mean difference 3.3–7.7) with an average blast count of 29.5 per 200 leukocytes. The regression limits of agreement, calculated as the 95 % predictive interval for individual differences, ranged from –5.4 to +9.6 cells and from –2.2 to +13.2 cells for the indicated levels, respectively. Conclusion. Mindray MC-80 can be used for preliminary digital pre-classification and screening detection of blasts; however, automated counting requires mandatory expert verification by a morphologist, especially when making clinical decisions near diagnostic thresholds.

About the Authors

D. M. Medetova
Federal State Budgetary Institution “Almazov National Medical Research Centre” of the Ministry of Health of the Russian Federation
Russian Federation

Dina M. Medetova, Student

St. Petersburg 


Competing Interests:

The authors declare no conflict of interest 



Yu. I. Karpova
Federal State Budgetary Institution “Almazov National Medical Research Centre” of the Ministry of Health of the Russian Federation

Yulia I. Karpova, MD, PhD, Associate Professor, Associate Professor, Laboratory Medicine and Clinics Department


Competing Interests:

The authors declare no conflict of interest 



V. S. Vlasov
Federal State Budgetary Institution “Almazov National Medical Research Centre” of the Ministry of Health of the Russian Federation
Russian Federation

Vladimir S. Vlasov, MD, PhD, Assistant, Laboratory Medicine and Clinics Department

St. Petersburg 


Competing Interests:

The authors declare no conflict of interest 



D. D. Kovaleva
Federal State Budgetary Institution “Almazov National Medical Research Centre” of the Ministry of Health of the Russian Federation
Russian Federation

Darya D. Kovaleva, Graduate student, Laboratory Medicine and Clinics Department

St. Petersburg


Competing Interests:

The authors declare no conflict of interest 



N. Yu. Chernysh
Federal State Budgetary Institution “Almazov National Medical Research Centre” of the Ministry of Health of the Russian Federation
Russian Federation

Natalia Yu. Chernysh, MD, PhD, Associate Professor, Associate Professor, Laboratory Medicine and Clinics Department

St. Petersburg 


Competing Interests:

The authors declare no conflict of interest 



Yu. V. Mirolyubova
Federal State Budgetary Institution “Almazov National Medical Research Centre” of the Ministry of Health of the Russian Federation
Russian Federation

Yulia V. Mirolyubova, MD, PhD, Assistant, Laboratory
Medicine and Clinics Department

St. Petersburg 


Competing Interests:

The authors declare no conflict of interest 



T. V. Vavilova
Federal State Budgetary Institution “Almazov National Medical Research Centre” of the Ministry of Health of the Russian Federation
Russian Federation

Tatyana V. Vavilova, MD, DSc, Professor, Head, Laboratory Medicine and Clinics Department

St.Petersburg


Competing Interests:

The authors declare no conflict of interest 



References

1. Khoury JD, Solary E, Abla O, et al. The 5th edition of the World Health Organization Classification of Haematolymphoid Tumours: Myeloid and Histiocytic/Dendritic Neoplasms. Leukemia. 2022;36(7):1703–19. doi:10.1038/s41375-022-01613-1.

2. Palmer L, Briggs C, McFadden S, et al. ICSH recommendations for the standardization of nomenclature and grading of peripheral blood cell morphological features. Int J Lab Hematology. 2015;37(3):287–303. doi:10.1111/ijlh.12327.

3. Fuentes-Arderiu X, Dot-Bach D. Measurement uncertainty in manual differential leukocyte counting. Clinical Chemistry and Laboratory Medicine. 2009;47(1). doi:10.1515/CCLM.2009.014.

4. Matek C, Krappe S, Münzenmayer C, et al. Highly accurate differentiation of bone marrow cell morphologies using deep neural networks on a large image data set. Blood. 2021;138(20):1917–27. doi:10.1182/blood.2020010568.

5. Kratz A, Lee S, Zini G, et al. Digital morphology analyzers in hematology: ICSH review and recommendations. Int J Lab Hematology. 2019;41(4):437–47. doi:10.1111/ijlh.13042.

6. Fan BE, Yong BSJ, Li R, et al. From microscope to micropixels: A rapid review of artificial intelligence for the peripheral blood film. Blood Reviews. 2024;64:101144. doi:10.1016/j.blre.2023.101144.

7. Kim H, Hur M, d’Onofrio G, Zini G. Real-World Application of Digital Morphology Analyzers: Practical Issues and Challenges in Clinical Laboratories. Diagnostics. 2025;15(6):677. doi:10.3390/diagnostics15060677.

8. El Alaoui Y, Elomri A, Qaraqe M, et al. A Review of Artificial Intelligence Applications in Hematology Management: Current Practices and Future Prospects. J Med Internet Res. 2022;24(7):e36490. doi:10.2196/36490.

9. Shen D, Wu G, Suk HI. Deep Learning in Medical Image Analysis. Annu Rev Biomed Eng. 2017;19(1):221–48. doi:10.1146/annurev-bioeng-071516-044442.

10. Ye X, Fang L, Chen Y, et al. Performance comparison of two automated digital morphology analyzers for leukocyte differential in patients with malignant hematological diseases: Mindray MC -80 and Sysmex DI- 60. Int J Lab Hematology. 2024;46(3):457–65. doi:10.1111/ijlh.14227.

11. Zhao Y, Diao Y, Zheng J, et al. Performance evaluation of the digital morphology analyser Sysmex DI-60 for white blood cell differentials in abnormal samples. Sci Rep. 2024;14(1):14344. doi:10.1038/s41598-024-65427-0.

12. Asghar R, Kumar S, Shaukat A, Hynds P. Classification of white blood cells (leucocytes) from blood smear imagery using machine and deep learning models: A global scoping review. Rajaraman S, editor. PLoS ONE. 2024;19(6):e0292026. doi:10.1371/journal.pone.0292026.

13. Deltadahl S, Gilbey J, Van Laer C, et al. Deep generative classification of blood cell morphology. Nat Mach Intell. 2025;7(11):1791–803. doi:10.1038/s42256-025-01122-7.

14. Xu W, Jiang H, Zhang J, et al. Evaluating AI in leukocyte classification: performance of the AI system against 15 morphology experts. npj Digit Med. 2026; 9(1):460. doi:10.1038/s41746-026-02601-w.

15. Khongjaroensakun N, Chaothai N, Chamchomdao L, et al. White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC-80. Int J Lab Hematol. 2023;45(5):691–9. doi:10.1111/ijlh.14119 PubMed PMID: 37338111.

16. Merino A, Laguna J, Rodríguez-García M, et al. Performance of the new MC-80 automated digital cell morphology analyser in detection of normal and abnormal blood cells: Comparison with the CellaVision DM9600. Int J Lab Hematol. 2024; 46(1):72–82. doi:10.1111/ijlh.14178 PubMed PMID: 37746889.

17. Zini G, Barbagallo O, Scavone F, Béné MC. Digital morphology in hematology diagnosis and education: The experience of the European LeukemiaNet WP10. Int J Lab Hematol. 2022; 44 Suppl 1:37–44. doi:10.1111/ijlh.13908 PubMed PMID: 36074713.


Review

For citations:


Medetova D.M., Karpova Yu.I., Vlasov V.S., Kovaleva D.D., Chernysh N.Yu., Mirolyubova Yu.V., Vavilova T.V. Detection of blast cells on the Mindray MC-80 automatic blood cell analyzer. Translational Medicine. 2026;13(4):388-398. (In Russ.) https://doi.org/10.18705/2311-4495-2026-13-4-388-398

Views: 37

JATS XML


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2311-4495 (Print)
ISSN 2410-5155 (Online)